H3100 G0 |
|||||
---|---|---|---|---|---|
Number of Beds | 6 | ||||
Bed Diameter | 14”-48” | ||||
Maximum Operating Pressure | 450 psig | ||||
Feed Capacity (NCMH) | 1,200-15,500 | ||||
Feed Gas Temp (°C) | 10-60 with 20-45 preferred | ||||
Design Standards | North America: ASME, NFPA, NEC, CSA / Europe: PED, ATEX, IEC | ||||
Voltage | 120Vac/1ph/60Hz, 240Vac/3ph/50 or 60Hz, 380Vac/3ph/50Hz, 480Vac/3ph/60Hz | ||||
Power Consumption | 0.2-0.5 kw typical | ||||
Design Life | 15+ years with scheduled maintenance, 10+years for adsorbents | ||||
Recommended Service | Inspection every 2.5 years; Minimum seal life 5 years |
Typical Hydrogen Source Gas
Feed Process Gas (vol%) | H2 | CO | CO2 | CH4 | CH2-3 | CH4 + | N2 | H2O Vapor |
---|---|---|---|---|---|---|---|---|
MSR SYNGAS | 60-80 | 0-10 | 10-20 | 0-10 | Sat. | |||
ATR SYNGAS | 40-60 | 0-10 | 15-25 | 0-10 | 0-30 | Sat. | ||
CPOX SYNGAS | 30-50 | 0-10 | 15-25 | 0-10 | 0-20 | Sat. | ||
GASIFICATION GAS | 20-60 | 0-20 | 0-20 | 0-20 | 0-10 | 0-5 | 0-10 | Sat. |
REFINERY OFF-GAS | 30-90 | 0-30 | 0-30 | 0-30 | 0-30 | 0-5 | Sat. | |
H2 POLISHING | 90-99 | Sat. | ||||||
AMMONIA CRACKING | 60-75 | 25-50 |
Performance
H2 PURITY | Up to 99.9999 % |
RECOVERY | 80-90 % typical. Recovery depends strongly on feed gas composition, pressure and product purity requirements. |
TURNDOWN | 40-100 % |
AVAILABILITY | Up to 99.9999 % |
APPLICATIONS |
|
Specifications
H-series Frame Size |
Vessel Outside Diameter |
Rotary Valve / # of Beds |
Max Op.Pressure | Feed Flow Capacity1 | Dimensions3 | Weight2 | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Width | Depth | Height | ||||||||||||
PSIG | BARG | SNFM | Nm3/hr | ft | m | ft | m | ft | m | lbs | kgs | |||
H-3100 | 14" | G0-6BED | 450 | 31 | 750 | 1,200 | 10.5 | 3.2 | 9.0 | 2.7 | 12.0 | 3.6 | 15,000 | 6,800 |
16" | 1,000 | 1,600 | 10.7 | 3.3 | 9.3 | 2.8 | 12.0 | 3.6 | 16,000 | 7,300 | ||||
18" | 1,250 | 2,000 | 10.9 | 3.3 | 9.3 | 2.8 | 12.0 | 3.6 | 17,000 | 7,700 | ||||
20" | 1,600 | 2,550 | 11.1 | 3.4 | 9.5 | 2.9 | 12.0 | 3.6 | 19,000 | 8,600 | ||||
24" | 2,300 | 3,700 | 11.6 | 3.5 | 10.0 | 3.0 | 12.0 | 3.6 | 21,000 | 9,500 | ||||
30" | 3,900 | 6,000 | 12.6 | 3.8 | 11.0 | 3.3 | 12.0 | 3.6 | 24,000 | 11,000 | ||||
36" | 5,350 | 8,500 | 13.6 | 4.1 | 12.0 | 3.6 | 16.2 | 4.9 | 28,000 | 17,000 | ||||
42" | 7,400 | 11,700 | 14.6 | 4.4 | 13.0 | 4.0 | 16.2 | 4.9 | 32,000 | 14,500 | ||||
48" | 9,800 | 15,500 | 15.6 | 4.7 | 14.0 | 4.3 | 16.2 | 4.9 | 36,000 | 16,300 |