GAS

Conditioning

Regenerative natural gas dryers

STRNGX-D DUAL TOWER

Ivys is a world leader in the drying of natural gas for refueling stations, with major installations around the globe, and has partnered with Exxon, Suncor, Sinopec and Petro China. Ivys dryers are ASME code compliant and National Board certified, and can be custom-built to specification.

Features

  • Rugged, skid-mounted double towers
  • Closed-loop, operator-initiated, heat-reactivated regenerated cycles for reliable control and shutdown
  • AutoDew is standard and will signal when regeneration is required
  • Manual valve switching between towers
  • No downtime

Applications

  • Medium to high flows
  • Low- to medium-pressure designs
  • Recommended for medium-throughput fueling needs

Certifications
Image accreditationImage accreditationImage accreditationImage accreditationImage accreditationImage accreditation

Specifications

Model No. Connection Capacity (approx.)
MMSCF @ 7#H20/MMSCF (E3Nm3@ 112 mg H20/m3)
Inlet Gas Flow (approx.) scfm (Nm3/hr) @ 100psig (7 barg) 1 Approximate Weight & Dimensions
Width inches (mm) Length inches (mm) Height inches (mm) Weight lbs (kg)
STR18NGX-1.5D 1-½" NPT 5.60 (151) 454 (730) 68 (1724) 85 (2159) 95 (2413) 3195 (675)
STR24NGX-2D 2" NPT 2 x 10.30 (276) 748 (1203) 80 (2032) 108 (2743) 94 (2388) 5400 (2430)
STR24NGX-3D 3" FIG 2 x 10.30 (276) 1369 (2204) 89 (2261) 124 (3150) 94 (2388) 5933 (2670)
STR30NGX-3D 3" FLG 2 X 16.70 (447) 1647 (2651) 99 (2515) 103 (2616) 102 (2591) 9601 (4321)
STR30NGX-4D 4" FLG 2 x 16.70 (447) 2205 (3550) 90 (2286) 160 (4064) 110 (2794) 8732 (3929)
STR36NGX-4D 4" FLG 2 x 23.20 (621) 2836 (4566) 102 (2591) 156 (3962) 126 (3200) 11500 (5175)
STR42NGX-4D 4" FLG 2 x 36.80 (985) 2836 (4566) 149 (3785) 158 (4015) 135 (3430) 11600 (5220)
STR42NGX-6D 6" FLG 2 x 36.80 (985) 5211 (8390) 149 (3785) 158 (4015) 135 (3430) 12100 (5445)

Standard pressure models (150 psig). Contact our experts for higher pressure or flow requirements.

1 Flow conditions given for reference only. Please contact factory for sizing at different flow pressure conditions.
  Standard conditions are 1 ATM at 6O °F. Normal conditions are 1 ATM at O°C.