Air
Conditioning
Carbon tower
ECOTROC CTAP OIL VAPOR ADSORBERS
KSI
Capacity up to 65 cfm
Residual oil content to: < 0.003 mg/m³ at 68°F
Oil aerosols up to 0.01 mg/m³ can be extracted by filtration technology. If higher quality compressed air is required oil vapour can be adsorbed by a classical ECOTROC activated carbon adsorber. The result is an exceptionally high air quality with a residual oil content down to 0.003 mg/m³. The ECOTROC CT product group can be divided into the lighter CTAP aluminium version, CTN standard welded version and the CTF version with flange connection.
![ECOTROC_CTAP_OIL_VAPOUR_ADSORBERS_1](https://ivysads.com/wp-content/uploads/2024/03/ECOTROC_CTAP_OIL_VAPOUR_ADSORBERS_1.jpg)
Advantages
Specifications
Performance data and dimensions
Type* | Capacity** | Dimensions (inch) | Connection | Weight | Grp. | ||||
---|---|---|---|---|---|---|---|---|---|
cfm | A | B | C | D | Intlet | Outlet | lbs | ||
CTAP6 | 6 | 27.32 | 25.00 | 9.69 | 7.09 | 3/8“ | 3/8“ | 18 | 320 |
CTAP12 | 12 | 31.26 | 28.94 | 9.69 | 7.09 | 3/8“ | 3/8“ | 20 | 320 |
CTAP20 | 20 | 32.76 | 30.20 | 12.32 | 8.27 | 3/8“ | 3/8“ | 35 | 320 |
CTAP30 | 30 | 36.73 | 34.13 | 12.32 | 8.27 | 3/8“ | 3/8“ | 37 | 320 |
CTAP35 | 35 | 40.67 | 38.07 | 12.32 | 8.27 | 1/2“ | 1/2“ | 49 | 320 |
CTAP40 | 40 | 36.65 | 33.86 | 14.80 | 9.84 | 1/2“ | 1/2“ | 57 | 320 |
CTAP55 | 55 | 42.17 | 39.37 | 14.80 | 9.84 | 1/2“ | 1/2“ | 66 | 320 |
CTAP65 | 65 | 49.25 | 46.46 | 15.75 | 9.84 | 1/2“ | 1/2“ | 71 | 320 |
*calculated at 14.5 psi (abs.) and 68°F at 101.5 psi working pressure
Correction factors
Correction factors inlet temperature | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
°F | <77 | 77 | 86 | 95 | 100.4 | 104 | 113 | 118.4 | 122 | ||||||||||||||||
F(t) | 1.2 | 1.1 | 1.09 | 1 | 0.84 | 0.78 | 0.72 | 0.65 | 0.58 |
Correction factors operating pressure | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | 58 | 65 | 73 | 80 | 87 | 94 | 102 | 109 | 116 | 123 | 131 | 138 | 145 | 152 | 160 | 167 | 174 | 181 | 189 | 196 | 203 | 210 | 218 | 225 | 232 |
F(p) | 0.6 | 0.7 | 0.74 | 0.82 | 0.89 | 0.97 | 1 | 1.08 | 1.11 | 1.16 | 1.22 | 1.29 | 1.36 | 1.42 | 1.5 | 1.57 | 1.63 | 1.69 | 1.75 | 1.83 | 1.9 | 1.96 | 2.03 | 2.1 | 2.14 |
Multiply the capacity of the dryer by the correction factor in the table above and you will get the corrected capacity.
Higher inlet temperatures on request.