Air

Conditioning

Carbon tower

ECOTROC CTN OIL VAPOUR ADSORBERS

KSI

Capacity up to 65 cfm

Residual oil content to: < 0.003 mg/m³ at 68°F

Oil aerosols up to 0.01 mg/m³ can be extracted by filtration technology. If higher quality compressed air is required oil vapour can be adsorbed by a classical ECOTROC activated carbon adsorber. The result is an exceptionally high air quality with a residual oil content down to 0.003 mg/m³. The ECOTROC CT product group can be divided into the lighter CTAP aluminium version, CTN standard welded version and the CTF version with flange connection.

Features

CTN 90 - CTN 705

  • Optimal adsorption of oil vapor (hydrocarbons)
  • High active activated carbon for air and gases brings maximum efficiency
  • Optimized volume flow distribution over the entire activated carbon bed
  • Residual oil content up to maximum: < 0.003 mg/m³
  • Oil indicator for checking the saturation level, standard starting with ATC 15
  • Easy accessibility for uncomplicated maintenance 10,000 hours of activated carbon service life*.

*The application time of the activated carbon depends on the quality and the relative humidity of the medium, as well as the type of compressor.


Advantages

  • Optimized adsorption of oil vapor (hydrocarbons)
  • Highly activated carbon for air and gases ensures maximum efficiency
  • Optimized volume flow diversion through the whole activated carbon bed
  • Residual oil content up to maximum 0.003 mg/m³
  • Oil indicator monitors the saturation stage, standard from model CTN105 and larger (optional for CTAP)
  • Easy access to all components simplifies maintenance
  • 8 000 hours activated carbon life time*

Specifications

Performance data and dimensions

Type Capacity* Dimensions (inch) Connection Weight Grp.
cfm A B C D Intlet Outlet lbs
CTN105 105 54.41 53.62 27.4 22.64 1“ 1“ 198 325
CTN125 125 59.29 58.5 27.4 22.64 1“ 1“ 276 325
CTN200 200 60.63 59.49 27.4 27.56 1 1/2“ 1 1/2“ 353 325
CTN285 285 64.53 63.39 27.4 27.56 1 1/2“ 1 1/2“ 375 325
CTN350 350 82.64 81.5 27.4 27.56 1 1/2“ 1 1/2“ 463 325
CTN480 480 74.45 70.2 33.86 33.27 2“ 2“ 761 325
CTN590 590 83.43 82.01 33.86 33.27 2“ 2“ 882 325
CTN705 705 87.36 85.94 33.86 33.27 2“ 2“ 926 325

*calculated at 14.5 psi (abs.) and 68°F at 101.5 psi working pressure

Correction factors

Correction factors inlet temperature
°F <77 77 86 95 100.4 104 113 118.4 122
F(t) 1.2 1.1 1.09 1 0.84 0.78 0.72 0.65 0.58
Correction factors operating pressure
psi 58 65 73 80 87 94 102 109 116 123 131 138 145 152 160 167 174 181 189 196 203 210 218 225 232
F(p) 0.6 0.7 0.74 0.82 0.89 0.97 1 1.08 1.11 1.16 1.22 1.29 1.36 1.42 1.5 1.57 1.63 1.69 1.75 1.83 1.9 1.96 2.03 2.1 2.14

Multiply the capacity of the dryer by the correction factor in the table above and you will get the corrected capacity.

Higher inlet temperatures on request.

Get a quote

    Regarding the requested equipment

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Get your quote within 24-48hrs