Air
Conditioning
Carbon tower
ECOTROC CTN OIL VAPOUR ADSORBERS
KSI
Capacity up to 65 cfm
Residual oil content to: < 0.003 mg/m³ at 68°F
Oil aerosols up to 0.01 mg/m³ can be extracted by filtration technology. If higher quality compressed air is required oil vapour can be adsorbed by a classical ECOTROC activated carbon adsorber. The result is an exceptionally high air quality with a residual oil content down to 0.003 mg/m³. The ECOTROC CT product group can be divided into the lighter CTAP aluminium version, CTN standard welded version and the CTF version with flange connection.
![ECOTROC_CTN_OIL_VAPOUR_ADSORBERS_1](https://ivysads.com/wp-content/uploads/2024/03/ECOTROC_CTN_OIL_VAPOUR_ADSORBERS_1.jpg)
Advantages
Specifications
Performance data and dimensions
Type | Capacity* | Dimensions (inch) | Connection | Weight | Grp. | ||||
---|---|---|---|---|---|---|---|---|---|
cfm | A | B | C | D | Intlet | Outlet | lbs | ||
CTN105 | 105 | 54.41 | 53.62 | 27.4 | 22.64 | 1“ | 1“ | 198 | 325 |
CTN125 | 125 | 59.29 | 58.5 | 27.4 | 22.64 | 1“ | 1“ | 276 | 325 |
CTN200 | 200 | 60.63 | 59.49 | 27.4 | 27.56 | 1 1/2“ | 1 1/2“ | 353 | 325 |
CTN285 | 285 | 64.53 | 63.39 | 27.4 | 27.56 | 1 1/2“ | 1 1/2“ | 375 | 325 |
CTN350 | 350 | 82.64 | 81.5 | 27.4 | 27.56 | 1 1/2“ | 1 1/2“ | 463 | 325 |
CTN480 | 480 | 74.45 | 70.2 | 33.86 | 33.27 | 2“ | 2“ | 761 | 325 |
CTN590 | 590 | 83.43 | 82.01 | 33.86 | 33.27 | 2“ | 2“ | 882 | 325 |
CTN705 | 705 | 87.36 | 85.94 | 33.86 | 33.27 | 2“ | 2“ | 926 | 325 |
*calculated at 14.5 psi (abs.) and 68°F at 101.5 psi working pressure
Correction factors
Correction factors inlet temperature | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
°F | <77 | 77 | 86 | 95 | 100.4 | 104 | 113 | 118.4 | 122 | ||||||||||||||||
F(t) | 1.2 | 1.1 | 1.09 | 1 | 0.84 | 0.78 | 0.72 | 0.65 | 0.58 |
Correction factors operating pressure | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | 58 | 65 | 73 | 80 | 87 | 94 | 102 | 109 | 116 | 123 | 131 | 138 | 145 | 152 | 160 | 167 | 174 | 181 | 189 | 196 | 203 | 210 | 218 | 225 | 232 |
F(p) | 0.6 | 0.7 | 0.74 | 0.82 | 0.89 | 0.97 | 1 | 1.08 | 1.11 | 1.16 | 1.22 | 1.29 | 1.36 | 1.42 | 1.5 | 1.57 | 1.63 | 1.69 | 1.75 | 1.83 | 1.9 | 1.96 | 2.03 | 2.1 | 2.14 |
Multiply the capacity of the dryer by the correction factor in the table above and you will get the corrected capacity.
Higher inlet temperatures on request.