Air

Conditioning

Modular dessicant air dryers

ECOTROC DDAP DESICCANT DRYERS HEATLESS REGENERATED

KSI

Pressure dew point down to -40°F

Capacity up to 130 scfm

Desiccant dryers are used in environments where a specified pressure dew point of -40°F to -94°F must be reliable and safe. Dryers of the ECOTROC DD series are available in three versions: as a compact aluminum series (DDAP) for volume flows up to 110 cfm, with welded vessels (DDN) for volume flows up to 705 cfm as well as in the large version (DDF) up to 1800 cfm*. Higher volume flows are available on request.

Features

Compact series · DDAP6 - DDAP130

  • Protection of production & processes ► longer service cycles for machines and installations
  • High-value desiccants ► constant pressure dew points, constant air quality
  • Minimized energy requirements ► lowers operating costs
  • Maximized operating reliablility ► protection against production and machine failure
  • Best industrial equipment quality ► long service cycles and lifetime
  • Intelligent control ► comfortable comfortable operability and operation
  • Brand system components ► simple maintenance
  • High serviceability ► minimizes service costs
  • Simple and safe assembly ► quick commissioning
  • Optional up to -94°F

Advantages

The ECOTROC DDAP Plus-Effects

  • Change of desiccant via filling and emptying openings
  • Filling nozzles eliminate the need for laborious removal of the plates
  • Simple and clear service packages
  • Easy to understand control unit, simple menu navigation (with ETC 4.0)
  • The two service blocks on the upper and lower plate contain all the parts required for service. After simple disassembly, all service work is carried out in a relaxed posture, eliminating the need for laborious work directly on the dryer. Important: The dryer remains installed in the overall installationrn

ATTRIBUTES AND BENEFITS

  • Two large-dimensioned silencers ► risk of clogging with desiccant dust virtually eliminated
  • Use of quality drying agents ► more safety in performance
  • Stlid construction
  • Floor fixation possibandard pre and post filtration ► system safety
  • Regeneration gas recirculation included as standard
  • Delivery of ready-to-connect units
  • Robust and sole
  • DDAP6 and DDAP12 can optionally be supplied with wall mounting bracket
  • Modular approach

Specifications

Performance data and dimensions

Type* Capacity** Dimensions (inch) Connection Installed power Electric voltage Frequency
cfm A B C D Intlet Outlet HP V Hz
DDAP6 6 28.43 25.00 15.51 12.17 3/8" 3/8" 0.042 115 50/60
DDAP12 12 32.36 28.94 15.51 12.68 3/8" 3/8" 0.042 115 50/60
DDAP20 20 34.29 30.20 18.90 16.93 3/8" 3/8" 0.042 115 50/60
DDAP30 30 38.23 34.13 18.90 16.93 3/8" 3/8" 0.042 115 50/60
DDAP35 35 42.17 38.07 18.90 16.93 1/2" 1/2" 0.042 115 50/60
DDAP40 40 38.54 33.86 21.73 17.80 1/2" 1/2" 0.042 115 50/60
DDAP55 55 44.06 39.37 21.73 17.80 1/2" 1/2" 0.042 115 50/60
DDAP65 65 51.14 46.46 23.62 17.80 1/2" 1/2" 0.042 115 50/60
DDAP80 80 38.43 22.44 29.96 31.69 1" 1" 0.042 115 50/60
DDAP110 110 43.94 22.44 29.96 31.69 1" 1" 0.042 115 50/60

*calculated at 14.5 psi (abs.) and 68°F at 101.5 psi working pressure

Correction factors

Correction factors inlet temperature
°F <77 77 86 95 100.4 104 113 118.4 122
F(t) 1.2 1.1 1.09 1 0.84 0.78 0.72 0.65 0.58
Correction factors operating pressure
psi 58 65 73 80 87 94 102 109 116 123 131 138 145 152 160 167 174 181 189 196 203 210 218 225 232
F(p) 0.6 0.7 0.74 0.82 0.89 0.97 1 1.08 1.11 1.16 1.22 1.29 1.36 1.42 1.5 1.57 1.63 1.69 1.75 1.83 1.9 1.96 2.03 2.1 2.14

Multiply the capacity of the dryer by the correction factor in the table above and you will get the corrected capacity.

Higher inlet temperatures on request.

Range of application

installation site inside non-aggressive atmosphere
ambient humidity max. 25% r.h 37% r.h 50% r.h 70% r.h 90% r.h
at 104°F at 95°F at 86°F at 77°F at 68°F
ambient temperature max. 122°F
ambient temperature min. 35.6°F
operating pressure 58 up to 232 psi (DDAP65: up to 195.75 psi)
flow medium compressed air and gases
pressure dew point -40°F* (-94°F optionally available)

*calculated at 14.5 psi (abs.) and 68°F at 101.5 psi working pressure

Get a quote

    Regarding the requested equipment

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Get your quote within 24-48hrs